Home » High
Tension Insulators
We offer high tension insulators, pin
insulators that provides high electric insulation. These are suitable for
both indoor as well as outdoor purposes. The salient features of the product
includes dimensional accuracy, efficient performance in complex weather
conditions and robust construction.
Pin Insulator 11 kv
We offer pin insulators, high tension
pin insulators that features 11 kv are made of high grade wet process and
are normally brown glazed. These pin insulators are efficient and safe. The
11KV insulators are fabricated with immense precision and care to ensure it
has high functional utility and long functional life.
 |
 |
|
SC-PN-1101
|
SC-PN-1102
|
|
STANDARD PARTICULARS |
|
 |
| Drawing No. |
|
|
SC-PN 1101 |
| Highest System Voltage |
|
kV |
12 |
| Working Voltage |
|
kV |
11 |
| Creepage Distance Minimum |
|
mm |
230 |
| Visible Discharge Voltage |
|
kV |
9 |
| Mechanical Failing Load |
|
kN |
5 |
| Power Frequency Withstand Voltage |
|
|
|
|
Wet |
kV |
35 |
|
Dry |
kV |
45 |
| Power Frequency Flash over Voltage |
|
|
|
|
Wet |
kV |
45 |
|
Dry |
kV |
55 |
| Impulse Withstand Voltage |
|
kVp |
75 |
| Puncture Voltage |
|
kV |
105 |
| Thimble IS : 2486 (Part II) / BS : 3288
(Part II) |
|
|
Small |
| Net Weight (Approx) |
|
kg. |
1.0 |
Specification as per IS : 731, BS : EN 60383, IEC :
383
|
 |
|
STANDARD PARTICULARS |
|
 |
| Drawing No. |
|
|
SC-PN 1102 |
| Highest System Voltage |
|
kV |
12 |
| Working Voltage |
|
kV |
11 |
| Creepage Distance Minimum |
|
mm |
280 |
| Visible Discharge Voltage |
|
kV |
9 |
| Mechanical Failing Load |
|
KN |
10 |
| Power Frequency Withstand Voltage |
|
|
|
|
Wet |
kV |
35 |
|
Dry |
kV |
45 |
| Power Frequency Flashover Voltage |
|
|
|
|
Wet |
kV |
45 |
|
Dry |
kV |
55 |
| Impulse Withstand Voltage |
|
kVp |
75 |
| Puncture Voltage |
|
kV |
105 |
| Thimble-IS: 2486(Part-II)/BS:3288(Part-II) |
|
|
Small/Large |
| Net Weight (approx) |
|
Kg. |
1.2 |
Specification as per IS : 731, BS : EN 60383, IEC :
383
|
 |
 |
 |
|
SC-PN-1103
|
SC-PN-1104
|
|
STANDARD PARTICULARS |
|
 |
| Drawing No. |
|
|
SC-PN 1103 |
| Highest System Voltage |
|
kV |
12 |
| Working Voltage |
|
kV |
11 |
| Creeping Distance Minimum |
|
mm |
280 |
| Visible Discharge Voltage |
|
kV |
9 |
| Mechanical Failing Load |
|
KN |
10 |
| Power Frequency withstand Voltage |
|
|
|
|
Wet |
kV |
35 |
|
Dry |
kV |
45 |
| Power Frequency Flash over Voltage |
|
|
|
|
Wet |
kV |
45 |
|
Dry |
kV |
55 |
| Impulse Withstand Voltage |
|
kVp |
75 |
| Puncture Voltage |
|
kV |
105 |
| Thimble - IS : 2486 ( Part II) / BS : 3288
(Part II) |
|
|
Small / Large |
| Net Weight (approx) |
|
Kg. |
1.5 |
Specification as per IS : 731, BS : EN 60383, IEC :
383
|
 |
|
|
|
 |
STANDARD PARTICULARS
| Drawing No. |
|
|
SC-PN1104 |
| Highest System Voltage |
|
kV |
12 |
| Working Voltage |
|
kV |
11 |
| Creepage Distance Minimum |
|
mm |
320 |
| Visible Discharge Voltage |
|
kV |
9 |
| Mechanical Failing Load |
|
KN |
10 |
| Power Frequency Withstand Voltage |
|
|
|
|
Wet |
kV |
35 |
|
Dry |
kV |
45 |
| Power Frequency Flashover Voltage |
|
|
|
|
Wet |
kV |
45 |
|
Dry |
kV |
55 |
| Impulse Withstand Voltage |
|
kVp |
75 |
| Puncture Voltage |
|
kV |
105 |
| Thimble- IS : 2486 (Part II) / BS : 3288
(Part II) |
|
|
Small / Large |
| Net Weight (approx) |
|
Kg. |
2.2 |
Specification as per IS : 731, BS : EN 60383, IEC 383
|
 |
Pin Insulator 22 kv
We offer a range of 22 kv Pin
Insulators that includes both one piece or multipiece construction. These
Pin insulators are available with special head grooves to accommodate
special conductor fastenings can be manufactured based on client's
specifications.
 |
 |
|
SC-PN-2201
|
SC-PN-2202
|
 |
|
SC-PN-3302
|
|
STANDARD PARTICULARS |
|
 |
| Drawing No. |
|
|
SC-PN 2201 |
| Highest System Voltage |
|
kV |
24 |
| Working Voltage |
|
kV |
22 |
| Total Creepage Distance (Nominal) |
|
mm |
432 |
| Protected Creepage Distance (Nominal) |
|
mm |
210 |
| Visible Discharge Voltage |
|
kV |
18 |
| Mechanical Failing Load |
|
KN |
10 |
| Power Frequency Withstand Voltage |
|
|
|
|
Wet |
kV |
55 |
|
Dry |
kV |
65 |
| Power Frequency Flashover Voltage |
|
|
|
|
Wet |
kV |
65 |
|
Dry |
kV |
75 |
| Impulse Withstand Voltage |
|
|
|
|
Positive |
kVp |
140 |
|
Negative |
kVp |
150 |
| Puncture Voltage |
|
kV |
140 |
| Thimble-IS: 2486 (Part ll) / BS:3288(Part
II) |
|
|
Large |
| Net Weight (approx) |
|
Kg. |
4.5 |
Specification as per IS : 731, BS : EN 60383, IEC :
383
|
 |
|
STANDARD PARTICULARS |
|
 |
| Drawing No. |
|
|
SC-PN 2202 |
| Highest System Voltage |
|
kV |
24 |
| Working Voltage |
|
kV |
22 |
| Total Creepage Distance (Nominal) |
|
mm |
560 |
| Protected Creepage Distance (Nominal) |
|
mm |
290 |
| Visible Discharge Voltage |
|
kV |
18 |
| Mechanical Failing Load |
|
KN |
10 |
| Power Frequency Withstand Voltage |
|
|
|
|
Wet |
kV |
75 |
|
Dry |
kV |
85 |
| Power Frequency Flashover Voltage |
|
|
|
|
Wet |
kV |
85 |
|
Dry |
kV |
95 |
| Impulse Withstand Voltage |
|
kVp |
|
|
Positive |
|
150 |
|
Negative |
|
160 |
| Puncture Voltage |
|
kV |
150 |
| Thimble-IS: 2486 (Partll) / BS:3288(Part II) |
|
|
Large |
| Net Weight (approx) |
|
Kg. |
6 |
Specification as per IS: 731, BS:EN 60383, IEC: 383.
|
 |
|
STANDARD PARTICULARS |
|
 |
| Drawing No. |
|
|
SC-PN 3302 |
| Highest System Voltage |
|
kV |
36 |
| Working Voltage |
|
kV |
33 |
| Total Creepage Distance (Nominal) |
|
mm |
670 |
| Protected Creepage Distance (Nominal) |
|
mm |
325 |
| Visible Discharge Voltage |
|
kV |
27 |
| Mechanical Failing Load |
|
KN |
10 |
| Power Frequency Withstand Voltage |
|
|
|
|
Wet |
kV |
80 |
|
Dry |
kV |
95 |
| Power Frequency Flashover Voltage |
|
|
|
|
Wet |
kV |
90 |
|
Dry |
kV |
105 |
| Impulse Withstand Voltage |
|
|
|
|
Positive |
kVp |
190 |
|
Negative |
kVp |
200 |
| Puncture Voltage |
|
kV |
200 |
| Thimble-IS: 2486 (Par-ll) / BS:3288(Part II) |
|
|
Large |
| Net Weight (approx) |
|
Kg. |
10.0 |
Specification as per IS: 731, BS:EN 60383, IEC: 383
|
 |
Pin Insulator 33kv
We offer Pin Insulators 33kv of one
piece or multipiece construction that are widely used in low cost
distribution lines. We manufacture full range of pin insulators for
application in sub-transmission and distribution lines. Our insulators are
tested and guaranteed for cantilever strength and are provided with adequate
margin of safety. We offer these Pin Insulators with customization.
 |
|
SC-PN-3301
|
|
STANDARD PARTICULARS |
|
 |
| Drawing No. |
|
|
SC-PN 3301 |
| Highest System Voltage |
|
kV |
36 |
| Working Voltage |
|
kV |
33 |
| Total Creepage Distance (Nominal) |
|
mm |
580 |
| Protected Creepage Distance (Nominal) |
|
mm |
300 |
| Visible Discharge Voltage |
|
kV |
27 |
| Mechanical Failing Load |
|
KN |
10 |
| Power Frequency Withstand Voltage |
|
|
|
|
Wet |
kV |
75 |
|
Dry |
kV |
85 |
| Power Frequency Flash over Voltage |
|
|
|
|
Wet |
kV |
85 |
|
Dry |
kV |
95 |
| Impulse Withstand Voltage |
|
|
|
|
Positive |
kVp |
170 |
|
Negative |
kVp |
180 |
| Puncture Voltage |
|
kV |
180 |
| Thimble-IS: 2486 (Part ll) / BS:3288(Part
II) |
|
|
Large |
| Net Weight (approx) |
|
Kg. |
7 |
Specification as per IS : 731, BS:EN 60383, IEC : 383
|
 |
Transformer bushings 17.5 , 24 &
36 kv
Our Transformer Bushings featuring
17.5, 24 & 36 KV represent a combination of competent design with
skilled manufacturing process. Inherent porcelain shells strength and
electrical properties fulfill the requirement of all international
standards. Dimensions of porcelain parts of insulators and bushings are
based on voltages and ampere ratings of transformer.
 |
|
SC-B-1201
|
|
STANDARD PARTICULARS |
|
 |
| Drawing No. |
|
SC-B-1201 |
| Transformer Rating |
|
12, 17.5kV/250 Amp. |
| Visible Discharge Voltage |
kV |
9 |
| Power Frequency one minute Dry |
kV |
45 |
| Withstand Voltage Wet |
kV |
40 |
| Impulse withstand Voltage |
kVp |
95 |
| Net Weight (approx.) |
Kg. |
3.2 |
Specification : IS : 1445, BS : 137
|
 |
 |
|
SC-B-2401
|
|
STANDARD PARTICULARS |
|
 |
| Drawing No. |
|
SC-B-2401 |
| Transformer Rating |
|
24kV/250 Amp. |
| Visible Discharge Voltage |
kV |
18 |
| Power Frequency one minute Dry |
kV |
60 |
| Withstand Voltage Wet |
kV |
65 |
| Impulse withstand Voltage |
kVp |
125 |
| Net Weight (approx.) |
Kg. |
6 |
Specification : IS : 1445, BS : 137
|
 |
 |
|
SC-B-3601
|
|
|
|
 |
| Drawing No. |
|
SC-B-3601 |
| Transformer Rating |
|
36kV/250 Amp. |
| Visible Discharge Voltage |
kV |
27 |
| Power Frequency one minute Dry |
kV |
80 |
| Withstand Voltage Wet |
kV |
75 |
| Impulse withstand Voltage |
kVp |
170 |
| Net Weight (approx.) |
Kg. |
8 |
Specification : IS : 1445, BS : 137
|
 |